Appendix A: Troubleshooting & Maintenance - Talk-a-Phone WEBS-PA-1 Configuration And Operation Manual

Hide thumbs Also See for WEBS-PA-1:
Table of Contents

Advertisement

Appendix A: Troubleshooting & Maintenance
Problem
Unable to access the
Communications
Module's Web GUI
Unable to login to
the Communications
Module's Web GUI
Unable to receive
incoming pages
38
Possible Causes & Corrective measures
1
The IP address being used in the Web browser is incorrect.
Connect the serial console and check the WEBS-PA-1's IP
address.
2
IP address of the Communications Module is conflicting with
another network device. Reassign a new IP address to the
WEBS-PA-1.
3
The Communications Module's Web server is not responding.
Reboot the Communications Module.
1
The Communications Module's database is corrupt. Reset to
factory default settings using the Reset button (Refer to 7.4
Factory Settings).
1
The Communications Module is not on the network. Check
network settings.
2
The Communications Module is not registered with a WEBS
®
Contact
Server. Check Paging settings.
Appendix A: Troubleshooting & Maintenance
Talk-A-Phone Co.

Advertisement

Table of Contents
loading

Table of Contents