Using the Web GUI

4.7.6 Firmware Upgrade

The Firmware Upgrade page is used to update the Communications Module to new firmware
releases.
Login → Maintenance → Firmware Upgrade
To upgrade the firmware:
1
Select either the FTP or HTTP protocol to download the firmware image.
2
Enter the Server IP Address, Username
and password is preferred to be retained for a future upgrade, select the Save Username and
Password check box.
3
In the Filename box, enter the filename with its complete path. The filename is generally in the
format of (EVP_A_B_C_D). This filename needs to be prefixed with directory relative to the HTTP
or FTP root directory. For example, /tftpboot/EVP_images/EVP_1_0_0_0). Consult the
Administrator for FTP/HTTP settings.
4
Select the Upgrade check box.
5
Click Apply. One of the following progress messages is displayed:
7
The maximum number of characters in username is 30.
8
The maximum number of characters in password is 30.
29
5
Figure 14 Firmware Upgrade
7
, and Password