LED Indicators Instructions
Protection
Battery
/ Alarm /
Status
Normal
Shut Down
Sleep
Normal
Normal
Alarm
Idle
Protection
Normal
Alarm
Charge
Protection
Normal
Discharge
Alarm
Protection
Power On
Fault
Abnormal
Other Fault
STL Fault
Note: The flashing instructions, flash 1 - 0.25s light / 3.75s off; flash 2 - 0.5s light / 0.5s off; flash 3 -
0.5s light / 1.5s off; flash 4 - 1s light / 1s off.
STATUS
STATUS
(green)
(red)
● ● ● ●
Off
Off
Off
Flash2
Off
Off
Light
Off
Off
Light
Off
Off
Off
Light
Off
Light
Off
indicator LED flashes (flash
Light
Off
Off
Light
Off
Flash2
Off
Flash2
Off
Off
Light
Off
Off
flash 4
Off
Off
light
Off
Off
flash 2
Capacity SOC
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
The highest capacity
2), others lighting
Off
Off
Off
Indicate based on
capacity
Off
Off
Off
Off
Off
Off
Off
Off
Off
flash 2
15
Descriptions
All off
Indicates Sleep Mode,
to save the power.
Indicates save power
mode.
Indicates the battery
voltage or
temperature is high or
low.
Indicates the battery
voltage or
temperature is over or
under.
The highest capacity
indicator LED flashes
(flash 2), others lighting,
horse race lamp when
SOC>= DODH;
Stop charging,
STATUS(red) lighting
Indicate based on
capacity
Stop discharging,
STATUS(red) lighting
Stop
charging/discharging,
STATUS(red) lighting
MCU self-check
problem

Advertisement