The Drive has 6 multi-function contact digital inputs. By programming parameters H1-01 through H1-06, the user can assign specific
functions to each input. Below is a table with a complete list of all of the digital input functions according to control method (A1-02).
Not all functions are available for all control methods. Following the table is a more detailed description of each of the functions.
Parameter
Setting
0
3-Wire Control
1
Local/Remote Selection
2
Option/Inverter Selection
3
Multi-Step Frequency Reference 1 (factory default, H1-03)
4
Multi-Step Frequency Reference 2 (factory default, H1-04)
5
Multi-Step Frequency Reference 3
6
Jog Frequency Reference (factory default, H1-05)
7
Accel/Decel Time Selection 1
8
External Baseblock N.O. (factory default, H1-06)
9
External Baseblock N.C.
A
Accel/Decel Ramp Hold
B
External Overheat Alarm (OH2)
C
Terminal A2 Enable
D
V/f Control with PG Disabled
E
ASR Integral Reset
F
Terminal Not Used
10
MOP Increase
11
MOP Decrease
12
Forward Jog
13
Reverse Jog
14
Fault Reset (factory default, H1-02)
15
Fast-Stop N.O.
16
Motor 2 Selection
17
Fast-Stop N.C.
18
Timer Function
19
PID Disable
1A
Accel/Decel Time Selection 2
1B
Program Lockout
1C
Trim Control Increase
1D
Trim Control Decrease
1E
Reference Sample Hold
20
External Fault, Normally Open, Always Detected, Ramp To Stop
21
External Fault, Normally Closed, Always Detected, Ramp To Stop
22
External Fault, Normally Open, During Run, Ramp To Stop
23
External Fault, Normally Closed, During Run, Ramp To Stop
External Fault, Normally Open, Always Detected, Coast to Stop
24
(factory default, H1-01)
25
External Fault, Normally Closed, Always Detected, Coast To Stop
26
External Fault, Normally Open, During Run, Coast To Stop
27
External Fault, Normally Closed, During Run, Coast To Stop
28
External Fault, Normally Open, Always Detected, Fast-Stop
29
External Fault, Normally Closed, Always Detected, Fast-Stop
2A
External Fault, Normally Open, During Run, Fast-Stop
2B
External Fault, Normally Closed, During Run, Fast-Stop
2C
External Fault, Normally Open, Always Detected, Alarm Only
2D
External Fault, Normally Closed, Always Detected, Alarm Only
2E
External Fault, Normally Open, During Run, Alarm Only
2F
External Fault, Normally Closed, During Run, Alarm Only
30
PID Integral Reset
31
PID Integral Hold
32
Multi-Step Reference 4
34
PID Soft Starter Cancel
Table 13 Multi-Function Input Selection
Function
Programming 70
Control Method (A1-02)
Open
V/f with
V/f
Loop
PG
Vector
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
X
X
O
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Flux
Vector
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents