Parameter
Parameter Name
No.
Digital Operator Display
DO-02/DO-08 Channel 1
F5-01
Output Selection
DO Ch1 Select
DO-02/DO-08 Channel 2
F5-02
Output Selection
DO Ch2 Select
DO-08 Channel 3 Output
F5-03
Selection
DO Ch3 Select
DO-08 Channel 4 Output
F5-04
Selection
DO Ch4 Select
DO-08 Channel 5 Output
F5-05
Selection
DO Ch5 Select
DO-08 Channel 6 Output
F5-06
Selection
DO Ch6 Select
DO-08 Channel 7 Output
F5-07
Selection
DO Ch7 Select
DO-08 Channel 8 Output
F5-08
Selection
DO Ch8 Select
DO-08 Output Mode
F5-09
Selection
DO-08 Selection
Operation Selection after
F6-01
Communication Error
Comm Bus Flt Sel
Selection of External Fault
from Communication Option
F6-02
Board
EF0 Detection
Stopping Method for
External Fault from
F6-03
Communication Option
Board
EF0 Fault Action
Trace Sampling from
Communications Option
F6-04
Board
Trace Sample Tim
Current Monitor Display Unit
F6-05
Selection
Current Unit Sel
Torque reference/torque limit
selection from
F6-06
communications option
Torq Ref/Lmt Sel
Denotes that parameter can be changed when the Drive is running.
Table A.1 F7 Parameter List (Continued)
Description
DO-02, 08 Setup
Sets the digital output function number for channel 1. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 2. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 3. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 4. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 5. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 6. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 7. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the digital output function number for channel 8. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the function of the DO-08 digital output option board.
0: 8-channel individual outputs.
1: Binary code output.
2: 8-channel Selected - Output according to F5-01 to F5-08 set-
tings.
Communications Option Setup
Selects the stopping method for a communication option board
fault (BUS). Active only when a communication option board is
installed and b1-01 or b1-02 = 3.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
Selects the condition in which an EF0 fault is detected from a
communication option board. Active only when a communication
option board is installed and b1-01 or b1-02 = 3.
0: Always detected
1: Detected only during operation
Selects the stopping method for an external fault from a
communication option board (EF0). Active only when a
communication option board is installed and b1-01 or b1-02 = 3.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
Sets the sample trace for the CP-916 option board.
Selects the current monitor scaling when using a communication
option board.
0: Displayed in Amps
1: 100%/8192 (12 bit binary number with 8192=100% Drive's
rated current)
Selects torque reference/limit when using communications option
board.
0: Disabled -Torque reference/limit from option board disabled
1: Enabled - Torque reference/limit from option board enabled.
Programming 170
Control Method
Setting
Factory
V/F
Range
Setting
V/F
w/
PG
0 to 37
0
A
A
0 to 37
1
A
A
0 to 37
2
A
A
0 to 37
4
A
A
0 to 37
6
A
A
0 to 37
37
A
A
0 to 37
F
A
A
0 to 37
F
A
A
0 to 2
0
A
A
0 to 3
1
A
A
0 to 1
0
A
A
0 to 3
1
A
A
0 to
0
A
A
60000
0 to 1
0
A
A
0 to 1
0
-
-
Open
Flux
Loop
Vector
Vector
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
-
A