F7 Parameter List - YASKAWA F7 Programming Manual

Hide thumbs Also See for F7:
Table of Contents

Advertisement

F7 Parameter List

Parameter
Parameter Name
No.
Digital Operator Display
A1-00
Language Selection
Select Language
A1-01
Access Level Selection
Access Level
Control Method Selection
A1-02
Control Method
Initialize Parameters
A1-03
Init Parameters
Password 1
A1-04
Enter Password
Password 2
A1-05
Select Password
User Parameter 1
A2-01
User Param 1
User Parameter 2
A2-02
User Param 2
User Parameter 3
A2-03
User Param 3
User Parameter 4
A2-04
User Param 4
User Parameter 5
A2-05
User Param 5
User Parameter 6
A2-06
User Param 6
User Parameter 7
A2-07
User Param 7
User Parameter 8
A2-08
User Param 8
User Parameter 9
A2-09
User Param 9
Denotes that parameter can be changed when the Drive is running.
Table A.1 F7 Parameter List
Description
Initialization
Language selection for the Digital Operator.
This parameter is not reset to the factory setting by A1-03.
0: English
1: Japanese
2: Deutsch
3: Francais
4: Italiano
5: Espanol
6: Portugues
Selects which parameters are accessible via the Digital Operator.
0: Operation Only
1: User Level (only available if A2 parameters have been set)
2: Advanced Level
Selects the Control Method of the Drive.
0: V/F control without PG
1: V/F control with PG
2: Open Loop Vector
3: Flux Vector (Closed Loop Vector)
Used to return all parameters to their factory or user default
settings. (Initializes and then returns A1-03 to zero.)
0: No Initialize
1110: User Initialize (The user must first set their own parameter
values and then store them using parameter o2-03.)
2220: 2-Wire Initialization
3330: 3-Wire Initialization
When the value set into A1-04 does NOT match the value set into
A1-05, parameters A1-01 thru A1-03 and A2-01 thru A2-32 cannot
be changed. All other parameters as determined by A1-01 can be
changed. Parameter A1-05 can be accessed by pressing the MENU
key while holding the RESET key.
User Parameters
Selects the parameters to be available in the User Access Level
(A1-01 = 1). These parameters are not related to the User Initialize
function.
Programming 153
Control Method
Setting
Factory
V/F
Range
Setting
V/F
w/
PG
0 to 6
0
A
A
0 to 2
2
A
A
0 to 3
2
Q
Q
0 to
0
A
A
3330
0 to
0
A
A
9999
0 to
0
A
A
9999
A
A
A
A
A
A
A
A
b1-01
to
A
A
o3-02
A
A
A
A
A
A
A
A
Open
Flux
Loop
Vector
Vector
A
A
A
A
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents