Parameter
Setting
36
PID Input
37
PID Output
38
PID Setpoint
44
ASR Output Without Filter
45
Feedforward Control Output
The analog output function selections above correspond to one of the same number U1-xx monitors in the Drive.
Function: Frequency Reference
Setting: 1
The analog output level will correspond to the chosen frequency reference input whether it is input via the digital operator,
analog input, serial communication, option board, or pulse input. 100% will be equivalent to the maximum output frequency
of the Drive (E1-04).
Function: Output Frequency
Setting: 2
The analog output level will correspond to the actual Speed being output by the Drive and will include the acceleration and
deceleration ramps. 100% will be equivalent to the maximum output frequency of the Drive (E1-04).
Function: Output Current
Setting: 3
The analog output level will correspond to the output current level of the Drive. 100% will be equivalent to the Drives rated
output current which is based on the rated capacity of the Drive (o2-04).
Function: Motor Speed
Setting: 5
The analog output level will correspond to the motor speed. 100% will be equivalent to the maximum output frequency of the
Drive (E1-04).
Function: Output Voltage
Setting: 6
Table 21 Analog Output Functions
Function
10 V
20mA
0
4mA
Fig. 77 Analog Output Signal Level as a Function of the Monitor Value
Programming 106
Control Method (A1-02)
V/f with
V/f
PG
O
O
O
X
X
100%
Monitor
Function Level
Open
Flux
Loop
Vector
Vector
O
O
O
O
O
O
O
O
O
X
X
O
X
X
O