Led Flash Reject Code Conditions; Table 23 Led Flash Reject Codes - JCM GLOBAL DBV Series Integration Manual

Hide thumbs Also See for DBV Series:
Table of Contents

Advertisement

LED F
R
C
LASH
EJECT
Table 23 lists the various LED Flash Reject Code causes & solutions for Banknotes
Normal
Performance
Operation
Test
LED
LED
Sequence
Sequence
Yellow
Yellow
(3)
(2)
Yellow
Yellow
(3)
(3)
Yellow
Yellow
(3)
(4)
Yellow
Yellow
(3)
(5)
Yellow
Yellow
(3)
(6)
Yellow
Yellow
(3)
(7)
Yellow
Yellow
(3)
(8)
Yellow
Yellow
(3)
(9)
Yellow
Green
(3)
(1)
Yellow
Green
(3)
(2)
Yellow
Green
(3)
(3)
P/N 960-000175R_Rev. A {EDP #233426}
®
DBV
Series Banknote Validator (DBV-400) Integration Guide
C
ODE
ONDITIONS

Table 23 LED Flash Reject Codes

Error
When adjusting Banknote data, Sensors detected an abnormal Banknote
magnification condition.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
Magnification
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Abnormal
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
The Validation Sensor detected an abnormal Banknote Type.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Denomination
unacceptable Banknote types.
Error
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
The Validation Sensor detected an abnormal Banknote Type.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Pattern Error
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
While transporting a Banknote, transparent tape was detected.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Photo Level Error
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
The Validation Sensors calculated a Banknote length longer or shorter than
the specified value.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
Banknote Length
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Abnormal
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
The Validation Sensors calculated that the 2-Color Banknote margin was
greater than the specified value.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
2-Color Margin
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Abnormal
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
The Banknote has been validated as a Counterfeit Banknote.
Counterfeiting
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
Banknote Action
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
unacceptable Banknote types.
The Validation Sensors calculated a 3-Color comparison that was greater
than the specified value.
3-Color
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to "Banknote Fitness Requirements" on page 4 for
Comparison
unacceptable Banknote types.
Abnormal
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
The Banknote has been inserted in an incorrect/crooked direction.
Skewed Insertion
[Solution] Insert a Banknote in the proper direction.
Error
If the error is not resolved, insert a different Banknote.
Remaining
While Initializing, a Banknote remaining in the DBV-400 Unit's Validation
Banknotes
path has been returned.
Returned
Sensors detected Banknotes remain in the validation path, or none existed
during an abnormal timing interval.
Banknote
[Solution] Check that the following parts are properly assembled and/or
Harness connected. Clean or adjust the following parts and Sensors.
Transportation
Abnormal
[Relative Parts] Entrance Sensor, Centering Guide Sensor, Validation
Sensor, PB Entrance Sensor, PB Exit Sensor, Exit Sensor.
If the error is not resolved, change the above related part or parts.
Causes and Solutions
© 2014, JAPAN CASH MACHINE CO., LTD.
3 3