2.7.4.1 Use Of The Temperature Input In Kty Mode; 2.7.4.2 Use Of The Temperature Input In Ptc Mode - KEB COMBIVERT F5 Series Instruction Manual

Hide thumbs Also See for COMBIVERT F5 Series:
Table of Contents

Advertisement

Connection Power Unit

2.7.4.1 Use of the temperature input in KTY mode

Connection of a KTY sensor
+
KTY84
KTY sensors may not be combined with other devices. Otherwise wrong meas-
urements would be the consequence.
Examples for the construction and programming of a temperature control with
KTY84 evaluation can be taken from the application manual.

2.7.4.2 Use of the temperature input in PTC mode

If the temperature input is operated in PTC mode, all possibilities are available for the user
within the specified resistance range. This can be:
Wiring example in PTC mode
Thermal contact (NC contact)
Temperature sensor (PTC)
Mixed sensor chain
The function can be switched off with Pn.12 = "7" (CP.28) if no evaluation of the input is
desired (standard in operating mode GENERAL). Alternatively a bridge can be installed be-
tween T1 and T2.
GB - 28
KTY sensors are poled semiconductors and must be
T1
operated in forward direction! Connect anode to T1 !
Non-observance leads incorrect measurement in the
upper temperature range. Protection of the motor wind-
T2
ing is no longer guaranteed.
T1
T2
T1
T2
T1
T2

Advertisement

Table of Contents
loading

Table of Contents