Event List

This section lists the events which occur in CC-Link IE TSN. The three event types are system, security, and operation.
The event type is displayed when the [Event History] button in the [Error Information] tab in the "Module Diagnostics" window
of the RJ71GN11-T2 is clicked. ( Page 166 Error Information)
System
Event
Overview
code
00100
Link-up
00141
CPU module time setting failure
00173
Co-recording trigger sending/receiving
00174
Co-recording trigger sending/receiving
00175
Co-recording trigger sending/receiving
00406
Slave station time synchronization completion
00407
Grandmaster selection (CC-Link IE TSN device)
00408
Grandmaster selection (general-purpose device)
00409
Own station time synchronization completion
00500
Own station: Network entry
00501
Another station: Network entry
00502
Network entry in all stations
0050A
Connection of a tool that supports the CC-Link IE
TSN
0050B
Disconnection of a tool that supports the CC-Link IE
TSN
00510
Own station: Data link restart (cyclic transmission
start)
00511
Another station: Data link restart (cyclic transmission
start)
00512
All stations data link normalization (all-station cyclic
transmission start)
00535
Another station: Reserved station enable setting
instruction execution
00540
Loopback resolution
00542
Own station: Receive frame error line status caution
level
00800
Link-down
00906
Alive check error
00907
Divided messages receive timeout error
00908
IP assembly timeout error
00909
TCP specification port number error
0090A
UDP specification port number error
00C00
Own station: Disconnection from network
00C01
Another station: Disconnection from network
00C02
Abnormal access response of another station
00C10
Own station: Data link stop (cyclic transmission stop)
00C11
Another station: Data link stop (cyclic transmission
stop)
00C21
Another station: Error occurrence
Cause
The system was linked up by connecting a device (such as an external device).
Setting of the time to the CPU module failed.
The co-recording trigger received from a CPU module has been sent to the network.
The co-recording trigger received from another station has been sent to the CPU
module.
The co-recording trigger received from another station has been sent to the network.
The slave station time synchronization has completed.
The CC-Link IE TSN device was selected as the grandmaster.
The general-purpose device was selected as the grandmaster.
The own station time synchronization has completed.
Own station enters the network.
Another station enters the network.
All stations enter the network.
A tool that supports the CC-Link IE TSN is connected.
A tool that supports the CC-Link IE TSN is disconnected.
Own station data link restarted.
Data link of another station restarted.
Data link returned to normal status at all stations.
Reserved station enable setting was executed at another station.
Loopback execution status was resolved when using a ring topology (using the loopback
function).
A receive frame error (line status: caution level) has occurred.
The system was linked down by removing a device (such as an external device).
The alive status of an external device could not be checked.
• Sufficient data for the data length could not be received.
• The remaining part of the divided message could not be received.
An IP assembly timeout error has occurred since the transient transmission load is high
or transient transmission time is not enough. (The remaining part of the divided data
could not be received and a timeout has occurred.)
The port number used in a connection already opened is set. (For TCP/IP)
The port number used in a connection already opened is set. (For UDP/IP)
Own station was disconnected from the network.
Another station was disconnected from the network.
• Abnormal response was returned from another station when accessing another
station.
• Abnormal response was returned to another station when accessed from another
station.
Own station data link was stopped.
Data link of another station was stopped.
An error has occurred in another station.
4 TROUBLESHOOTING
235
4.7 Event List