Error
Error definition and causes
code
1802H
During data link, overlapping IP addresses
have been detected.
1803H
Over the number of stations that can be
connected.
4 TROUBLESHOOTING
204
4.5 List of Error Codes
Action
Change the IP address of devices with an overlapped IP address.
■When the firmware version of the RJ71GN11-T2 is "04" or later
• Reduce the number of CC-Link IE TSN Class B devices and TSN hubs to
eight or less in total for each port of the master station in the transmission
path from the master station to the CC-Link IE TSN Class B device of the
end.
Do one or both of the following:
• Update the master station to a version that supports CC-Link IE TSN
protocol version 2.0.
• Update the firmware of the CC-Link IE TSN Class A device to the latest
version, or replace it with a device that supports CC-Link IE TSN protocol
version 2.0.
■When the firmware version of the RJ71GN11-T2 is "03" or earlier
• Reduce the total number of stations to 31 stations (master station: 1, slave
station: 30) or less.
• Configure the system with the number of CC-Link IE TSN Class B devices
to eight or less for each port of the master station.
Detailed
information 1
Detailed
information 2
■Operation source
information
• IP address
■IP address
duplication
information
• Duplication
station 1 MAC
address (1st
octet, 2nd octet)
• Duplication
station 1 MAC
address (3rd
octet, 4th octet)
• Duplication
station 1 MAC
address (5th
octet, 6th octet)
• Duplication
station 2 MAC
address (1st
octet, 2nd octet)
• Duplication
station 2 MAC
address (3rd
octet, 4th octet)
• Duplication
station 2 MAC
address (5th
octet, 6th octet)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn

Table of Contents