Restriction of firmware version
■Number of settable modules
The following table lists the number of settable modules in "Select Inter-module Synchronization Target Module" of the "Inter-
module Synchronization Setting" tab under "System parameter".
Firmware version of the RJ71GN11-T2
Firmware version "10"
Firmware version "11" or later
■Combination of the firmware versions
• To specify the multiple RJ71GN11-T2s as the target modules for the inter-module synchronization, use the RJ71GN11-T2
with the firmware version "11" or later. Do not use the RJ71GN11-T2 with the firmware version "10" and the RJ71GN11-T2
with the firmware version "11" or later together. Doing so results in Inter-module synchronization parameter mismatch (error
code: 3018H) or Inter-module synchronization abnormal error (error code: 360DH).
Number of settable modules
Master station
1
8
1.6 CC-Link IE TSN Network Synchronous Communication Function
Local station
1