No.
Name
Description
SW0110 to
CPU minor error
Stores the minor error occurrence status of each station.
SW0117
status of each
When the target station is the RJ71GN11-T2, the occurrence status on the CPU
station
module is stored.
0: Normal, or a moderate or serious error occurring
1: Minor error occurring
SW0110
SW0111
SW0112
SW0113
SW0114
SW0115
SW0116
SW0117
Each number in the table represents a station number.
 is fixed to 0.
(Conditions)
• Reserved stations and stations that surpass the maximum station number are
• Since a local station cannot obtain the station information of the CC-Link IE
SW0160 to
Execution result
When the slave station parameter automatic setting is completed with an error,
SW0167
of slave station
the bit of the target station is turned on.
parameter
Off: Completed successfully
automatic setting
On: Completed with an error
function
When completed with an error, the error code is stored in the SW0194.
When completed with an error caused by the master station, the bit is not turned
on.
SW0160
SW0161
SW0162
SW0163
SW0164
SW0165
SW0166
SW0167
Each number in the table represents a station number.
 is fixed to 0.
SW0194
Detailed
When the slave station parameter automatic setting is completed with an error,
execution result
the error code is stored.
of slave station
When completed with an error caused by the slave station, the bit of the target
parameter
station of 'Execution result of slave station parameter automatic setting function'
automatic setting
(SW0160 to SW0167) is turned on.
SW0198
Link dedicated
Stores the processing results of the link dedicated instruction that used channel 3
instructions
of the own station.
processing result
0: Completed successfully
CH3
1 or greater: Completed with an error (Error code is stored.)
SW0199
Link dedicated
Stores the processing results of the link dedicated instruction that used channel 4
instructions
of the own station.
processing result
0: Completed successfully
CH4
1 or greater: Completed with an error (Error code is stored.)
SW019A
Link dedicated
Stores the processing results of the link dedicated instruction that used channel 5
instructions
of the own station.
processing result
0: Completed successfully
CH5
1 or greater: Completed with an error (Error code is stored.)
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
16 15 14 13 12 11 10
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
ignored.
TSN Class A remote station when communicating in multicast mode, "0:
Normal, or a moderate or serious error occurring" is reflected to the CC-Link IE
TSN Class A remote station.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
16 15 14 13 12 11 10
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
9
8
7
6
5
4
3
2
1
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
1
120 119 118 117 116 115 114 113
Appendix 5 List of Link Special Register (SW)
Availability
Master
Local station
station
Unicast
Multicast
mode
mode
*1
APPX
A
281