Toro Greensmaster eFlex 1800 Diagnostic Manual page 86

Traction unit
Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

Pin Identification
Pin Identification
3. Check for a short between the following pins:
Location
1
2
Pass
Circuit continuity tested good and no shorts are identified at the listed locations. Go to
the Equipment to Service (page 19)
Fail
For those items that failed, repair or replace worn or damaged parts as required. Go to
the Equipment to Service (page 19)
Note: Do not replace the motor unless the fault repeats.
Step 11: Replace the motor (conditional).
If Steps 10.1 and 10.2 passed, and Fault 9 repeated immediately after returning the equipment to service, then replace the motor.
Go to
Returning the Equipment to Service (page 19)
P01 Battery Harness Li+ Connector
1
2
3
4
5
6
P04 Battery Harness Machine/Charger Connector
POS
P1
P2
S1
S2
NEG
Harness
Connector
Battery
Figure 80
Battery
Figure 80
Description
CAN + (High)
CAN – (Low)
42 to 64 Vdc Power
Ground
Battery Pack Wake Up
Not used
Description
42 to 64 Vdc Power
CAN + (High)
CAN – (Low)
Battery Pack Wake Up
Not used
Ground
Pin
P01
3
P01
4
and follow the steps listed.
and follow the steps listed.
and follow the steps listed.
86
Wire Color
Red/White (R/W)
Black/White (BK/W)
Red (R)
Black (BK)
Blue (BU)
Not used
Wire Color
Red (R)
Red/White (R/W)
Black/White (BK/W)
Blue (BU)
Not used
Black (BK)
Connector Graphic
1
3
2
5
6
4
Returning