Step 5.6: Test the TEC-2401 and associated wiring.
1. Connect the main wire harness P01 connector to the TEC-2401
2. Use a multimeter to measure the resistance between the main wire harness P37 connector, pins A and B
58). The reading should be 148 k to 181 k ohms (148,000 to 181,000).
Pass
The resistance reading was good. Go to Step 5.7.
Fail
If the resistance reading was not good, go to Step 5.6.1.
Step 5.6.1: Test the TEC-2401 wiring.
1. Disconnect the main wire harness P01 connector from the TEC-2401
2. Check for continuity between the following pairs of locations:
Location
1
2
1
2
1. Main wire harness P01 connector
2. Main wire harness P02 connector
Harness
Connector
Main
P37
Figure 58
Main
P01
Figure 66
Main
P37
Figure 58
Main
P01
Figure 66
Figure 66
Main Harness P01 and P02 Connector Pin Identification
(Figure
66).
Pin
A
11
B
12
3. TEC-2401 controller
67