Toro Greensmaster eFlex 1800 Diagnostic Manual page 7

Traction unit
Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

1. P05 molded cap (for storing P06 and P07)
2. P34
3. P07 battery wake (ground)
4. P06 battery wake (signal)
Additional Information
Li+ Diagnostic Wire
Harness Connector
P05 molded cap
P06 and P07 battery wake
P04 machine/charger
connector
P01 battery diagnostic
connector
P02 Toro DIAG cable
connector
Li+ Diagnostic Wire Harness Connector Identification
Description of Use
Protects connectors P06 and P07 when they are not in use
Connect the P06 and P07 connectors together momentarily allow the battery pack to "wake" from the
hibernate state so that you can determine the condition of the battery pack.
Connects the Li+ diagnostic wire harness to the battery wire harness P04 connector at the side of
the battery pack
Connects the Li+ diagnostic wire harness to the bottom of the battery pack after you raise the battery
pack
Connects the Toro DIAG USB/CAN cable to the battery pack
Figure 2
5. P04
6. P01 battery pack connector
7. P03 CAN bus terminator (120 ohm)
8. P02 Toro diagnostic connector
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster eflex 21000404204043

Table of Contents