Troubleshooting - BEA LZR FLATSCAN S User Manual

Compact laser scanner for perimeter and work of art protection
Table of Contents

Advertisement

TEACH-IN
RESET TO
FACTORY
SETTINGS
IMPORTANT: Test the good functioning of the installation before leaving the premises.

TROUBLESHOOTING

The ORANGE LED is on
permanently.
The ORANGE LED flashes
1 x /2 x /3 x every
1
3 seconds.
2
3
The ORANGE LED flashes
4 x every 3 seconds.
4
The ORANGE LED flashes
5
5 x every 3 seconds.
setting the field 1 through Teach-in.
setting the field 2 through Teach-in.
setting the background through Teach-in.
setting the field 1&2 through Teach-in.
Teach-in: the sensor can automatically learn its environment and its detection field. It
will adapt its detection field when the background changes.
reset all the parameters to factory settings.
reset the parameters outside of the detection field to factory settings.
The sensor encounters a
memory problem.
The sensor signals an
internal fault.
If the internal error still appears
after 3 resettings, the LED will
flash 9 times and the sensor
will be locked.
Masking or background error
Error during the
teach-in process.
3s
3s
3s
3s
3s
Send the sensor back for a technical check-up.
1
Cut and restore power supply.
2
If orange LED flashes again, send the sensor back
to manufacturer.
1
Remove any pollution on the front window
2
Check background and remove any object that could
provoke the error
Relaunch a teach-in process.
3s
max.30s
3s
max.30s
3s
max.30s
3s
max.30s
3s
30s
11

Advertisement

Table of Contents
loading

Table of Contents