TROUBLESHOOTING

Door remains closed,
LED off
Door does not react as
expected
Door does not react as
expected
3
Door opens and closes
repeatedly
Door opens for no
apparent reason
LED flashes quickly
after unlocking
Sensor does not
respond to remote
control
Door remains open,
LED stays on
Page 10 of 12
Sensor power is off
Door control (F2) is set to 3
(closed)
Incorrect output configuration
on the sensor
Wire to the antenna is
disconnected or damaged
The sensor is disturbed by
the door motion or vibrations
caused by the door motion
Sensor detects rain
Sensor detects objects outside
of its detection field (in highly
reflective environment)
Sensor detects movement of
the opposite door (in an airlock
vestibule)
Sensor requires access code to
unlock
Weak or incorrectly installed
batteries
Remote control not aimed at
sensor
Door control is set to "open"
Check the wiring and the power supply.
Change the door control setting (F2) to
value 1 (automatic).
Change the output configuration setting on
each sensor that is connected to the door
operator.
1. Check wire to the antenna.
2. If damaged, replace sensor.
1. Ensure the sensor is secured.
2. Ensure the detection mode is
unidirectional.
3. Increase antenna angle.
4. Increase immunity filter.
5. Reduce field size.
1. Ensure detection mode is unidirectional.
2. Increase immunity filter.
1. Change antenna angle.
2. Decrease field size.
3. Increase immunity filter.
1. Change antenna angle.
2. Adjust field shape.
3. Increase immunity filter.
1. Enter the correct access code.
2. If you forgot the code, cut and restore
the power supply to access the sensor
without access code.
3. Change or delete the access code.
Check batteries and change if necessary.
Point the remote control towards the
sensor.
Set the door control to "auto" (see pg. 8).