Main Functions; Digital In/Out Interface - JAI GO-5000M-PGE-UV User Manual

Cmos digital progressive scan monochrome uv camera with gige interface
Hide thumbs Also See for GO-5000M-PGE-UV:
Table of Contents

Advertisement

GO-5000M-PGE-UV User Manual (Ver. 1.2)

Main Functions

This chapter describes the camera's main functions.

Digital IN/OUT Interface

On this camera, the software control tool can assign the necessary signals used in the system to
digital inputs and outputs.
Line Selector
In the Line Selector, the following input and output signals can be assigned.
Line Selector Item
Line 1 Opt 1 Out
Line 2 Opt 2 Out
NAND 0 IN 1
NAND 0 IN 2
NAND 1 IN 1
NAND 1 IN 2
Line Source
Line source signal can be selected from the following table to connect it to the line item which is
selected in the line selector.
Line Source Item
Low
High
Acquisition Trigger Wait
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
Pulse Generator 0 Out
User Out 0
User Out 1
Opt 1 output from # 3 of DC In/Trigger 6-Pin on the rear
Opt 2 output from #4 of DC In/Trigger 6-Pin on the rear
No. 1 input to the first NAND gate
No. 2 input to the first NAND gate
No. 1 input to the second NAND gate
No. 2 input to the second NAND gate
Connect Low Level signal to line item selected in Line Selector (Default setting)
Connect High Level signal to line item selected in Line Selector
Connect Acquisition Trigger Wait signal to line item selected in Line Selector
Connect Frame Trigger Wait signal to line item selected in Line Selector
Connect Frame Active signal to line item selected in Line Selector
Connect Exposure Active signal to line item selected in Line Selector
Connect FVAL signal to line item selected in Line Selector
Connect Pulse Generator 0 signal to line item selected in Line Selector
Connect User Out 0 signal to line item selected in Line Selector
Connect User Out 1 signal to line item selected in Line Selector
Description
Description
- 29 -
Main Functions

Advertisement

Table of Contents
loading

Table of Contents