GO-5000M-PGE-UV User Manual (Ver. 1.2)

Pulse Generator

Tips for using the Pulse Generator
This camera has a frequency divider using the pixel clock as the basic clock and one pulse generator.
In the Pulse Generator, various Clear settings are connected to GPIO. The following shows the Pulse
Generator default settings.
Pulse Generator Default Settings
Display Name
Clock Pre-scaler 1
Pulse Generator
Pulse Generator
Scaler
Length Start Point
Pulse Generator
1
0
Note: When Pulse Generator Repeat Count is set to "0", the camera is operating in free-running
mode. However, based on the above default settings, Length=1, Start Point=0 and End Point=1,
Pulse Generator stops at High output. Therefore, if Start Point=0 and End Point=1 are configured,
Length should be "2" as the minimum active width.
Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit length) and
the pixel clock is used for this. On this camera, the pixel clock is set at 48MHz.
End
Repeat Count
Point
0
1
0
Value
Clear
Source
Off
- 36 -
Main Functions
Clear
Clear
Inverter
Activation
True
Off
Clear Sync
Mode
Asynch