Wire Size - Epever SolarV TRIRON Series User Manual

Mppt solar charge controller
Table of Contents

Advertisement

System
voltage
12V
24V
NOTE: The above parameter values are calculated under standard test conditions (STC (Standard
Test Condition): Irradiance 1000W/m

2.3 Wire Size

The wiring and installation methods must conform to national and local electrical code
requirements.
PV Wire Size
The PV array output varies with the PV module size, connection method, or sunlight angle. The PV
array Isc can calculate the minimum wire size. Please refer to the value of Isc in the PV module
specification. When PV modules are connected in series, the Isc equals the PV module Isc. When
PV modules are connected in parallel, the Isc equals the sum of the PV module's Isc. The Isc of the
PV array must not exceed the controller's maximum PV input current. Please refer to the table
below:
NOTE: All PV modules in a given array are assumed to be identical.
Isc=short circuit current(amps) Voc=open circuit voltage.
Model
TRIRON1206N
TRIRON1210N
TRIRON2206N
TRIRON2210N
TRIRON3210N
TRIRON3215N
TRIRON4210N
TRIRON4215N
These are the maximum wire sizes that will fit the controller terminals.
When the PV modules are connected in series, the open-circuit voltage of the
PV array must not exceed 46V (TRIRON**06N), 92V (TRIRON**10N), or 92V
CAUTION
(TRIRON**15N) at 25
Copyright© 2022 SolarV GmbH All rights reserved.
72cell Voc 46V
Max.
Best
2
1
3
2
2
, Module Temperature 25 , Air Mass1.5.)
Max. PV input current
environment temperature.
96cell Voc 62V
Max.
Best
1
1
2
1
10A
20A
30A
40A
9
Thin-Film Module
Voc 80V
1
1
Max. PV wire size
4mm
2
/12AWG
2
6mm
/10AWG
2
10mm
/8AWG
2
16mm
/6AWG