DB1
PV/BATT(orange)/Battery capacity lever(four) indicator
fast flashing
DS2
PV/BATT(orange)indicator fast flashing
The load is no output
DS1/DS2
/
Load and fault icon blink
Inverter fault
Inverter fault
Output short circuit
Output overload
Output voltage abnormal
Input over voltage
Input low voltage
Input over current
Overheating
Communication timeout
Fault code E002(only DS2)
Fault code E001(only DS2)
Fault code
LCD
Indicator
E001
E002
E003
Fault
E005
icon blink
indicator
E006
(1S)
E007
E008
E099
Copyright© 2022 SolarV GmbH All rights reserved.
Controller Overheating
System voltage error
Load Overload
Load Short Circuit
Load
WARNING
blink
43
When the controller heat sink exceeds 85
controller will automatically cut the input and output
circuit. When the temperature is below 75
controller will resume work.
Check whether the battery voltage matches the
controller's working voltage.
Please change to a suitable battery or reset the
working voltage.
Please reduce the number of electric equipment.
Restart the controller.
Wait for one night-day cycle (night time>3 hours).
Check the load connection and clear the fault.
Restart the controller.
Wait for one night-day cycle (night time>3 hours).
The controller connects our company's inverter
only, when it connects the purchased inverter, the
LCD shows E099.
With combination of the RCM and DS1/DS2
modules, the information of the inverter (to be
supplied by our company) can be displayed by the
DS1/DS2 module.
, the
, the