Epever SolarV TRIRON Series User Manual page 39

Mppt solar charge controller
Table of Contents

Advertisement

Connect the controller to the remote meter (MT50) through a standard network cable. After
selecting the battery type as "USE," set the voltage parameters by the MT50. Refer to the MT50
manual or aftersales engineer for details.
4
Controller parameters
Battery voltage parameters
Measure the parameters in the condition of 12V/25ºC. Please double the values in the 24V
system.
Battery type
Battery parameters
Over voltage disconnect
voltage
Charging limit voltage
Over voltage reconnect
voltage
Equalize charging voltage
Boost charging voltage
Float charging voltage
Boost reconnect charging
voltage
Low voltage reconnect
voltage
Under voltage warning
recover voltage
Under voltage warning
voltage
Low voltage disconnect
voltage
Discharging limit voltage
Equalize Duration
Boost Duration
Copyright© 2022 SolarV GmbH All rights reserved.
Sealed
GEL
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
14.6V
——
14.4V
14.2V
13.8V
13.8V
13.2V
13.2V
12.6V
12.6V
12.2V
12.2V
12.0V
12.0V
11.1V
11.1V
10.6V
10.6V
120 minutes
120 minutes
120 minutes
35
FLD
16.0V
15.0V
15.0V
14.8V
14.6V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
--
120 minutes
120 minutes
User
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
0 180
minutes
10 180
minutes