Safe Operation - Viking Oxeo PR LCP Operator's Manual

Inert gas extinguishing system
Table of Contents

Advertisement

Safety
Fire hazards
Do NOT use the system in conjunction with the following fire hazards:
Chemicals that release oxygen.
Mixtures containing oxidizing substances (e.g. sodium chlorate, sodium nitrate, explosives,
gunpowder).
Chemicals capable of thermally decomposing autonomously (e.g. certain organic perox-
ides).
Reactive metals (e.g. sodium, potassium, magnesium, titanium or zirconium) and reactive
hybrids or metal amides.
In certain circumstances, some of the mentioned fire types can be suppressed using IG-01
(argon). Consult the manufacturer about this.

2.4 Safe operation

If system components are used improperly or for other than their intended purpose, the sys-
tem in which they are used can pose hazards or be impaired. Only use undamaged and fully
functional products and machines. If safe operation can no longer be assured (e.g. due to visi-
ble damage), put the system out of operation without delay and secure against accidental
commissioning.
Also observe the following:
Use only original spare and wear parts.
Replace parts that are not in perfect condition immediately.
Do not carry out any changes, extensions or modifications without the express permission
of the manufacturer or distributor.
This also applies to welding work on load-bearing parts.
Any changes, extensions or modifications not approved by the manufacturer are the sole
responsibility and liability of the person making the modification and exclude any responsibility
of the manufacturer.
12
Operator's Manual | Oxeo PR LCP | F_101821 Rev 02 | 08-2022 | en

Advertisement

Table of Contents
loading

Related Products for Viking Oxeo PR LCP

Table of Contents