Opening And Closing The Coin Recycler's Payout Unit - CPI PAYPOD Embedded User Manual

Pay station
Hide thumbs Also See for PAYPOD Embedded:
Table of Contents

Advertisement

Paypod™ Embedded Pay Station
Close in reverse order and make sure that the bayonet
mount indication is green [4] and the coin validator arm is
down in its operating position [5] again.
4.9.3

Opening and Closing the Coin Recycler's Payout Unit

The coin payout unit can be opened and closed using the key for the lower lock to eliminate coin jam-
ming, for instance, or to service the coin recycler:
To open the payout unit the
1
If necessary, wait until a transaction has been finished.
2
Gain access to the coin recycler
3
Insert the key in the lower lock [1] and turn it counter-
clockwise as far as it will go [A].
4
Open the payout unit by the handle [2] as far as it will
go [B].
Opening the unit is supported by the gas springs.
44000-UG-01-01-EN_CPI_Paypod Embedded Pay Station_User Guide_V1.1.pdf
Hand over the key to open the payout unit only to personnel allowed to have direct
·
access to the cash.
Though the coin recycler stops running when the payout unit is open, you should al-
·
ways wait until a transaction has been finished before you open the payout unit to
not affect the coin counters.
57
lid must be closed
53
.
Published by CPI
Coin Recycler's Acceptance Unit Closed
.
Unlocking and Opening Coin Recycler's Payout Unit
Operation
59

Advertisement

Table of Contents
loading

Related Products for CPI PAYPOD Embedded

Table of Contents