Additional Fan; Pressure Sensor; Peak Load Signal; Peak Load Prevention - Miele PDR 914 Operating And Installation Instructions

Commercial tumble dryer
Table of Contents

Advertisement

Additional fan

External hardware is connected via the Miele XCI box.
If an extra fan is connected, it must be switched on at the same time as the drive unit.
- Off
- On

Pressure sensor

External hardware is connected via the Miele XCI box.
When using a shared exhaust air duct, one tumble dryer may have to be switched off or
suppressed from the outset if certain pressure levels have built up in the ducting.
Because the pressure sensor is an external unit, there is the option to add both a normally
open contact or a normally closed contact.
A message appears in the display while the exhaust air flap is open.
- Off = Not active
-
Normally open contact
Responds to high potential
Norm. closed contact
-
Responds to low potential

Peak load signal

External hardware is connected via the Miele XCI box.
The peak-load cut-out function enables the tumble dryer to be connected to an energy
management system. When a signal is registered, the tumble dryer's heater is switched
off for a short period or the appliance is prevented from being switched on.
The tumble dryer may only be operated with a peak-load system if this system is
connected to the tumble dryer via the Miele XCI Box.
- Factory setting: No function
- Peak load with 230 V
- Peak load with 0 V

Peak load prevention

With this function, the application of a hygiene programme is not amended when a peak
load signal is in place. The heater stays switched on.
- Factory setting: Off
- On

COM module selection

This tumble dryer is equipped with an integrated Wi-Fi module. However, the tumble
dryer can also be equipped with an external module.
- Off
= Active
= Active
Supervisor level
49