Supply Air/Exhaust Air; Steam Connection (Only For Steam-Heated Variants) - Miele PDR 914 Operating And Installation Instructions

Commercial tumble dryer
Table of Contents

Advertisement

If more than one voltage is specified on the data plate, the tumble
dryer can be converted for connection to the relevant input voltage.
This conversion must be performed by the Miele Professional Service
Department or by an authorised technician. During the conversion,
the wiring instructions given on the wiring diagram must be followed.
The tumble dryer can either be hard-wired or connected using a plug
and socket connection in accordance with IEC 60309-1. For a hard-
wired connection, an all-pole isolation device must be available at the
installation site.
When in the off position, this all-pole isolation device ensures a
3 mm gap between all open contacts. These include circuit
breakers, fuses and relays (IEC/EN 60947).
If the mains supply cannot be permanently disconnected, the
isolation device (including plug and socket) must be safeguarded
against being switched on either unintentionally or without
authorisation.
Useful tip: We recommend connecting the tumble dryer to the power
supply via a plug and socket so that it is easier to conduct electrical
safety checks (e.g. during maintenance or repair work).
The tumble dryer must not be connected to devices such as timers
which would switch it off automatically.
If the mains connection cable is damaged, it must be replaced by
the manufacturer, its service agent or similar qualified persons in
order to avoid a hazard.
Once the electrical connection has been established, the rotation
direction of the fan impeller must be checked. It must rotate
clockwise. If the fan impeller rotates anti-clockwise, two phases on
the mains terminal must be swapped.
If it is necessary to install a residual current device (RCD) in
accordance with local regulations, a residual current device type B
(sensitive to universal current) must be used.

Supply air/Exhaust air

The tumble dryer may only be operated when the ducting has been
connected and the room is sufficiently ventilated (see installation
instructions).

Steam connection (only for steam-heated variants)

The steam connection must only be carried out by a registered
installation technician. The enclosed installation instructions must be
observed as they are important for the steam connection.
Installation
35