F-Series ID Camera Installation
1.4

Camera Connections

GPIO Alarm
20 AWG MAX
3/4" NPT for Cable
Gland or Conduit
Back Cover
GPIO Alarm
Not used
GPIO
Alarms
Analog Video
1.4.1

Connecting power

The camera itself does not have an on/off switch. Generally the F-Series ID camera will be
connected to a circuit breaker and the circuit breaker will be used to apply or remove power to the
427-0033-00-12 Version 110
Male
BNC
Chassis
-
GND
Left
Cable
Gland
Analog Video
Local
Ground
Figure 1-3: Camera Connections
Figure 1-4: Connector locations
February 2019
This document does not contain any export-controlled information.
Camera
Power
Heater
Power
Ethernet
16 AWG
Shielded
Right
Cable
Gland
Ethernet
24
VAC/DC
Analog Video
(monitoring output only)
16 AWG
Shielded
24
VAC/DC
Camera Power
Heater Power
IP Network
11