Camera Connections; Connecting Power - FLIR D-348 Installation Manual

D-series
Table of Contents

Advertisement

1
D-Series Camera Installation
1
2
3
4
Select a water-tight enclosure for the connections that allows adequate space for the cable
connections. This requirement may vary, depending on the installation. Do not exceed the bend radius
per the recommendation of the cable manufacturer. The typical cable bend radius is 50 mm to 75 mm
(2-3 in).
1.8
Do not disassemble the camera, as it will void the camera warranty and could lead to damage if the
camera is not resealed properly.
1.8.1
The camera can be powered with a conventional AC or DC power supply. Prior to making any
connections, ensure the power supply or circuit breaker is switched off.
The power cable supplied by the installer must use wires that are sufficient size gauge for the supply
voltage and length of the cable run, to ensure adequate current carrying capacity (for most installations
18 AWG is recommended). Always follow local building/safety codes.
Note
The supplied connectors for the power connections will accept 16 AWG to 24 AWG wire size.
427-9030-01-12 Version 140
M5 bolt circle diameter 66 mm (2.598 in)
6X M5 X 0.8 fasteners, equally spaced at 60°; maximum fastener engagement 10 mm (.394 in)
1-1/2 in NPT threaded opening
Do not loosen or remove the cable gland nut; doing so could result in damage to the camera unit

Camera Connections

Connecting Power

Wire Color
Red
Black
Clear
Figure 1-3: Power Cable (3 conductor)
Table 1-1: Mounting Specifications
Table 1-2: Power Connections
Vac
Line
Neutral
Chassis
March 2018
Vdc
DC +
DC -
Chassis
9