Advanced Configuration
FoV until calibration is finished. The On-Screen Display shows the progress as a
percentage in the bottom left of the video (see Figure 3-1).
If the calibration takes too long, the scene may require manual calibration.
Step 4
After calibration is complete set up detection areas and check calibration. Refer to
Settings, pg.
41,
Manual Calibration
On the camera's Analytics web page, click the
Step 1
Calibrate icon.
Step 2
Select Manual for the Calibration mode.
Step 3
Set the near size aspect ratio for a person. Have
a person walk around at the bottom of the area.
Select the blue box at the bottom of the screen
and drag to fit the subject. Click Save.
4. Far Size
Calibration
3. Near Size
Calibration
Step 4
Set the far size aspect ratio for a person.
Have a person walk around at the top of the area. Select the blue box at the top of the
screen and drag to fit the subject. Click Save.
Step 5
After calibration is complete set up detection areas and check calibration. Refer to
Settings, pg.
41,
Based on these settings, the analytics calculate a human size that is proportional to the near and far
size calibration over the detection area. The vehicle size is extrapolated from the human size. If a
detected object matches these parameters, a box will be labeled either H for human, V for vehicle, or
O for object of interest.
427-0033-00-12 Version 110
Creating Analytics Regions, pg.
Figure 3-2: Manual Calibration
Creating Analytics Regions, pg.
February 2019
This document does not contain any export-controlled information.
42, and
Check Calibration, pg.
2
42, and
Check Calibration, pg.
Global
43.
1
Global
43.
40