E L E C T R I C A L S Y ST E M
6- 1 5
C heck t h e e l ectro l yte l eve l and add d ist i l l ed water,
as necessa ry to ra ise the e l ectro lyte to each cel l's
M AX . l eve l .
Check t h e battery fo r p rope r charge by tak i ng a n
el ectro lyte S. G . read i ng . I f t h e read i ng is 1 .22 o r
l ess, a s corrected to 20° C ( 68 ° F ) , it means that the
battery is sti l l in a ru n-down condition and needs
rec h a rgi n g .
N O T E :
8
F i rst, remove the
R E C H A RG I N G O P E RATI ON
BAS E D O N S . G . R EA D I NG
To read the S . G . o n the hyd ro meter, b r i n g the
el ectro lyte in the h yd rometer to eye l evel and read
the g raduations on the f l oat sca l e bordering on the
men iscus (cu rved - u p portion of e l ectro l yte su rface ) ,
a s shown i n fig u re.
C heck the rea d i ng (as co rrected to 20° C ) with
chart to determ i ne the recharg i ng time in hour by
constant-cu rrent charg i ng at a charg i ng rate of 1 .4
a m peres (wh ich is tenth of the ca pacity of the
p resent battery ) .
B e ca refu l not to permit the e l ectro l yte tem pera­
tu re to exceed 45° C ( 1 1 3° F ) , at any ti me, d u ri n g
the recha rg i ng operat i o n . I nterru pt the operation,
as necessa ry, to l et the e l ectro l yte coo l down .
R echarge the battery to the spec ification.
E lectro l yte specific
g ravity
CAUT I O N :
Constant-vol tage charg i ng, otherw i se cal led
"q u i c k" charg i ng, i s not recom mendab le fo r
it cou l d sho rten the l ife of the battery.
09900-28403
l ead w i re.
H yd rometer
1 . 29
>
1 . 28
-�
1 . 27
1 . 26
u
1 . 25
1 . 24
1 . 23
1!i
(f)
1 . 22
1 . 2 1
Temperatu re
o lL
1 . 28
ro
(0
u
1 . 24
0
0
N
1 . 20
>
+-'
1 . 1 6
>
Cl
. �
1 . 1 2
1 . 08
0
2
4
6
(f)
Charging t i m e ( h o u r )
8
1 0
1 2
1 4 1 6 1 8