Thales VesseLINK Certus 350 User Manual page 114

Hide thumbs Also See for VesseLINK Certus 350:
Table of Contents

Advertisement

Alert Name
BCX_IBIT_FAILURE
BCX_SIM
CN_OFF
CN_REBOOT
MODEM_ACT
MUX_PLL_UNLOCKED
PWR_IBIT_FAILURE
User Manual PN 84469 Rev L
Description
The BCX has failed "Initiated Built
In Self-Test" View Logs for details.
Modem failed to read SIM card
Core Node is powered off, restart
required
Core Node Reboot has occurred,
full system restart is required.
Modem returned an unknown error
– cannot activate
Antenna mux out-of-lock with the
modem.
The power has failed "Initiated Built
In Self-Test" View Logs for details.
Level
Additional Information
Fault
Warning
Critical
Core Node is noticed to be
unexpectedly off.
Critical
Core Node Module restarts
while the system is up and
running.
Fault
Critical
PLL failed to acquire
Fault
Corrective Action
Open
http://portal.thaleslink (or
https://portal.thaleslink)
and review Self-Test logs.
Restart the BDU. If
problem persists, contact
representative.
Remove, clean and re-
insert SIM. Contact
service provider if
problem persists.
Restart BDU. Contact
representative if problem
persists.
Restart BDU. Contact
representative if problem
persists.
Restart BDU. Contact
representative if problem
persists.
Restart BDU. Contact
representative if problem
persists.
Open
http://portal.thaleslink
(or
https://portal.thaleslink)
and review Self-Test logs.
Contact representative.
6-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vesselink certus 200

Table of Contents