Data Trace Recording Tool - Omron CS Series Operator's Manual

Cx-simulator
Hide thumbs Also See for CS Series:
Table of Contents

Advertisement

Error Processing
Symptoms
The specified output file could
not be generated from the tem-
plate file. Operation exit.
The specified output file does not
exist or its data is invalid. Opera-
tion exit
The target PLC was switched
from CX-Simulator to an actual
PLC. Operation exit.

10-1-5 Data Trace Recording Tool

Symptoms
--: Address(**) of bit area is out
of range.
--: Address(**) of word area is
out of range.
Cannot connect to PLC. PLC
communications error --.
Data Trace was started in man-
ual mode, failed to start in auto
mode.
Failed to execute Data Trace.
Because the parameters of the
file to be added are different
from setting parameters.
Failed to stop Data Trace.
Failed to open the destination
file for adding the Trace data.
Failed to save the sampling
data to --.
Failed to start Timer.
Sampling area is not specified.
Specified PLC type -- is not
supported. Data Trace will not
start.
The data of the setting file -- is
invalid.
236
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Causes
The file does not
Specify a Data Replay file or a template file of a cor-
exist or has a
rect format.
wrong format.
The file does not
Specify a Data Replay file (CSV text file) of a correct
exist or has a
format, which is different from an execution file of the
wrong format.
I/O Condition Tool.
The target PLC
The target PLC can not be changed while replaying
was changed
data.
while data replay-
ing.
If an error occurs while operating the Data Trace Recording Tool, the error
contents will be displayed in the dialog box. Remove the error causes refer-
ring to the remedies.
Causes
Correct the address referring to Appendix: Dialog box
for editing the address to be sampled.
Correct the address referring to Appendix: Dialog box
for editing the address to be sampled.
The target PLC
Check the FINS address for the target PLC.
does not exist.
Not possible of
Create the setting file again and start by the com-
automatic saving by
mand line.
the command line.
Communications
Restore to able-to-communicate state and try again.
disabled during
Data Trace.
The file format is
Specify another file name when Add saving and try
wrong when speci-
again. Remove the check mark of "Add saving."
fying "Add saving."
Wrong path name,
The file being used,
Read-only file, or
Low disk space
32 Windows timers
Exit some applications and try again.
are exhausted in
the whole system.
Register at least one address to either of word/bit
address.
The target PLC
Specify CS/CJ Series as a target PLC.
specifies other than
CS/CJ Series.
The contents of the
Create the setting file by [Parameters Save] again.
setting file are
wrong.
Remedies
Remedies
1. Specify the same values as the saved parame-
ters.
2. Remove the check mark of "Add saving" and try
again.
1. Check if the path name is correct.
2. Check if another application is using the file.
3. Check if read-only or the user is authorized to
write.
4. Check if disk space is enough.
Section 10-1