Error Processing

10-1-4 Data Replay Tool

Symptoms
A communications timeout oc-
curred. Operation exit.
An error response is received
from the target PLC. Operation
exit.
Command log data is invalid.
Operation exit.
Failed to connect to the PLC.
Operation exit.
Failed to open the Command log
file. Operation exit.
Failed to open the CSV text file.
Operation exit.
Failed to read the Command log
data. Operation exit.
Failed to read the CSV text data.
Operation exit.
Failed to start/stop the timer of
Windows. Operation exit.
Failed to write the CSV text data.
Operation exit.
Ladder stopped because of FAL
error on the target PLC. Opera-
tion exit.
Synchronous operation was
specified for the actual PLC.
Operation exit.
The data in CSV text file is inva-
lid. Operation exit.
The number of I/O address set-
tings exceeded the limit. Opera-
tion exit.
The specified I/O address is not
supported. Operation exit.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
If an error occurs while operating the Data Replay Tool, the error contents will
be displayed in the dialog box. Remove the error causes referring to the
remedies.
Causes
A timeout oc-
curred in a re-
sponse from the
Ladder Engine.
Wrong ad-
Check if wrong data are included in the Re-
dress/range of
play/Output file.
Replay data or
Output data.
The file has a
Specify a Command log file of a correct format.
wrong format.
Not possible to
Check the FINS address for the target PLC.
communicate with
the target PLC.
The file does not
Specify a Command log file of a correct format.
exist or has a
wrong format.
The file does not
Specify a Data Replay file (CSV text file) of a correct
exist or has a
format, which is different from an execution file of the
wrong format.
I/O Condition Tool.
The file has a
Specify a Command log file of a correct format.
wrong format.
A wrong format.
Specify a Data Replay file (CSV text file) of a correct
format, which is different from an execution file of the
I/O Condition Tool.
Windows system
call error.
Check the following causes:
Remove the causes and try again.
Tried to execute
Specify synchronous operation only for the Ladder
synchronous op-
Engine.
eration for other
than the Ladder
Engine.
A wrong format.
Specify a Data Replay file (CSV text file) of a correct
format, which is different from an execution file of the
I/O Condition Tool.
Exceeding the
The number of I/O address settings in the CSV text
limit of address
file must be less than 168.
setting in the CSV
text file.
A wrong file for-
Check if I/O address data of a wrong format are in-
mat.
cluded in the Replay/Output file.
Remedies
1. If the cycle time of the Ladder Engine is too long,
use synchronous processing in the virtual cycle
time.
2. Check if the target FINS address is the same as
that of the Ladder Engine.
1. Exit the applications excluding the CX-Simulator.
2. Restart the debugger.
1. Low disk space
2. Read -only file
3. Read-only folder
4. User unauthorized to write.
Section 10-1
235