Debug Console Window
Contents of Menu
Menu List of [Step Run] Window
Main Menu
Tasks
Help
Content of Pop-up Menu

3-9-9 I/O Break Condition Settings Window

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Name
Tasks
Help
Submenu
Cyclic tasks
Run Mode
Wait Mode
Block Run
Extra cyclic
Start
tasks
Stop
Activate Interrupt Task
Copy task data
Exit
Help Contents
Help Index
About
Clicking the task line and right-clicking will display the pop-up menu.
Name
Cyclic Task
Execution Mode
Standby Mode
Execution in Block Execute the selected cyclic task in block. Available
Interrupt Task Startup
Copy
Close
1. Block execution of task sets a start point at the top of the task and a break
Note
point at the bottom (END line), and operates in the same way as Step
Run.
2. Refer to 4-4 Task Debugging for the details of Task Control.
I/O Break Condition Setting sets the values of I/O memory with the logical
equation and registers the I/O Break Conditional Equation for breaking at the
step where the set equation holds.
Display the task menu.
Display the information on Help and the version.
Shortcut
Turn the selected cyclic task into the execution
mode.
Turn the selected cyclic task into the standby
mode.
Execute the selected cyclic task in block. Used in
Program mode.
Start the selected task as an extra cyclic task.
Stops the selected task.
In Program mode, execute the selected interrupt
task in block. In Monitor/Run mode, an interrupt
occurs at the moment and the process moves to
the specified interrupt task.
Copy the list of Task Control being displayed to
the clipboard.
Close the Task Control window.
Display the Help Contents
Display the Help Index.
Display the version information.
Turn the selected cyclic task to Execution mode.
Turn the selected cyclic task to Standby mode.
only in Program mode.
In Program mode, execute the selected interrupt task
in block. In Monitor/Run mode, an interrupt occurs at
the moment and the process moves to the specified
interrupt task.
Copy the list of Task Control being displayed to the
clipboard.
Close the Task Control window.
Section 3-9
Function
Function
Function