DHW Heating
Setting the Time Program for DHW Heating
22
Vitotronic 200-H, HK1B Operating
(continued)
Heating system with DHW circulation pump
For further information about the DHW circulation pump,
see chapter "Terminology".
H Automatic mode is set for the DHW circulation pump
time program. In other words, the DHW circulation
pump operates in parallel to the DHW heating time
program.
H If you don't want the automatic mode, you can select
up to 4 individual time phases per day for the DHW
circulation pump, which can be the same for every day
of the week or different. Set the start and end points
for each time phase.
H In the "Information" menu, you can scan the current
time program (see chapter "Scanning information",
"DHW" group).
Note: Activating the DHW circulation pump is only
advisable for those times when DHW is actually
drawn.
Extended menu:
1.
2. "DHW"
3. "DHW circ time prog"
4. "Individual"
5. Select part of the week or a day.
6. Select the time phase !, ?, § or $.
7. Set the start and end points for the relevant time
phase.
8. Press
to exit the menu.
Note: If you want to terminate a time phase setting
process prematurely, keep pressing
required display appears.
Deleting a time phase
Set the time for the end point to the same time that was
set for the start point. The display shows the selected
time phase "- - : - -".