Download Print this page

Toshiba e-STUDIO556 Service Manual page 712

Hide thumbs Also See for e-STUDIO556:

Advertisement

05/08
Mode
Element
Sub
element
08
Setting
System
General
Mode
08
Setting
System
User
Mode
interface
08
Setting
System
User
Mode
interface
08
Setting
System
User
Mode
interface
08
Setting
System
User
Energy save
Mode
interface
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
9103
9110
9111
9112
9113
Details
Default
Acceptable
code
value
value
Time differences
Refer to
0~47
contents
Auto-clear timer
3
0~10
setting
Auto power save
8
0, 4, 6~15
mode timer setting
Auto Shut Off Mode
2
0~21
timer setting (Sleep
Mode)
Screen setting for
Refer to
0~1
automatic energy
contents
saver / automatic
power OFF
143
RAM
Contents
SYS 0: +12.0h 1: +11.5h 2: +11.0h 3: +10.5h 4: +10.0h 5:
+9.5h 6: +9.0h 7: +8.5h 8: +8.0h 9: +7.5h 10: +7.0h 11:
+6.5h 12: +6.0h 13: +5.5h 14: +5.0h 15: +4.5h 16:
+4.0h 17: +3.5h 18: +3.0h 19: +2.5h 20: +2.0h 21:
+1.5h 22: +1.0h 23: +0.5h 24: 0.0h 25: -0.5h 26: -1.0h
27: -1.5h 28 -2.0h 29: -2.5h 30: -3.0h 31: -3.5h 32: -
4.0h 33: -4.5h 34: -5.0h 35: -5.5h 36: -6.0h 37: -6.5h
38: -7.0h 39: -7.5h 40: -8.0h 41: -8.5h 42: -9.0h 43: -
9.5h 44: -10.0h 45: -10.5h 46: -11.0h 47: -11.5h
<Default value>
JPC: 6
NAD: 40
MJD: 24
Others: 0
SYS Timer to return the equipment to the default settings
when the [START] button is not pressed after the
function and the mode are set.
0: No limit (disabled) 1 to 10: Set number x 15 sec.
SYS Timer to automatically switch to the Auto power save
mode when the equipment has not been used
0: Invalid 4: 1 min. 6: 3 min. 7: 4 min. 8: 5 min. 9: 7
min. 10: 10 min. 11: 15 min. 12: 20 min. 13: 30 min.
14: 45 min. 15: 60 min.
SYS Timer to enter the Sleep Mode automatically when the
equipment has not been used
0: 3 min. 1: 5 min. 2: 10 min. 3: 15 min. 4: 20 min. 5: 25
min. 6: 30 min. 7: 40 min. 8: 50 min. 9: 60 min. 10: 70
min. 11: 80 min. 12: 90 min. 13: 100 min. 14: 110 min.
15: 120 min. 16: 150 min. 17: 180 min. 18: 210 min. 19:
240 min. 20: Not used 21: 1 min.
SYS 0: OFF 1: ON
<Default value>
JPC/NAD: 1
Others: 0
Proce
Servic
dure
e UI
1
1
1
Yes
1
Yes
1
Yes

Hide quick links:

Advertisement

loading