Defective area
ERROR CODE AND TROUBLESHOOTING
Step
Check items
13
Has the appropriate paper type been
selected?
14
Is the setting temperature of the fuser
roller in each paper type normal?
15
Using the recommended paper?
16
Using the specified developer
material and toner?
17
Are the original glass (especially the
position of shading correction plate),
mirror and lens dirty?
8 - 242
Select a proper mode.
Check the setting and correct it.
08-2010, 08-2028, 08-2049, 08-
2050, 08-2051
Use the recommended paper.
Use the specified developer material
and toner.
Clean them.