05/08
Mode
Element
element
05
Adjustmen
Scanner
Scanner
Data transfer of
t mode
characteristic value
05
Adjustmen
Scanner
Scanner
t mode
05
Adjustmen
Scanner
RADF
t mode
05
Adjustmen
Scanner
Scanner
Shading correction
t mode
plate
Automatic dust
detection adjustment
05
Adjustmen
Scanner
RADF
EEPROM initialization
t mode
05
Adjustmen
Scanner
RADF
t mode
05
Adjustmen
Scanner
Scanner
Size detection of
t mode
original
05
Adjustmen
Scanner
Scanner
Size detection of
t mode
original
05
Adjustmen
Scanner
Scanner
Size detection of
t mode
original
e-STUDIO557/657/757/857
Item
Subitem
Code
3203
3209
3210
3218
3220
3221
3233
3234
3236
Sub-
Default
Acceptable
Details
code
value
value
SLG board -> SYS
-
board
Data transfer of
-
characteristic value of
scanner / SYS board
→ SLG board
Original reading start
-
sensor Auto adj.
Shading correction
-
plate
Automatic dust
detection adjustment
EEPROM initialization
-
Original reading start
-
sensor Manual adj.
Position adjustment in
Refer to
0-255
the primary scanning
contents
direction
Waiting position
200
0-255
adjustment of
carriage
Adjustment of lamp
128
0-255
lighting time
5
RAM
Contents
-
SYS Transfers the characteristic values of the scanner
(shading correction factor / RGB color correction /
reproduction ratio color deviation correction / shading
position correction factor / reproduction ratio correction
value in primary scanning direction)
-
SYS Transfers the characteristic values of the scanner
(shading correction factor / RGB color correction /
reproduction ratio color deviation correction / shading
position correction factor / reproduction ratio correction
value in primary scanning direction) from the SRAM of
the SYS board to the SRAM of the SLG board.
-
-
Perform the adjustment and initialization when the
RADF board or RADF original reading start sensor is
replaced.
-
-
Performs adjustment for automatic dust detection with
the shading correction plate. If dust is detected,
shading correction is performed by avoiding the dust.
-
-
Initializes EEPROM for the RADF.
-
-
Adjusts the RADF original reading start sensor of the
RADF manually.
SYS Adjusts the detection range for size of original.
<Default value>
NAD/TWD/CND: 128
Others: 58
SYS Adjusts the position where the carriage stops at the
size detection of the original.
Default value: 200 (20 mm from leading edge of
original)
Maximum value: 255 (25.5 mm from leading edge of
original)
Minimum value: 0 (0 mm from leading edge of original)
SYS Adjusts the lighting time of the lamp at the size
detection of the original.
Maximum value: 255 (Minimum time + 2040ms)
Minimum value: 0 (Minimum time)
Proce
Servic
dure
e UI