Check item
Setting
[8103]
Wireless Certificate verification failure
Classification
Network error
Check item
Setting
[8111]
SNMP writing access failure
Classification
Network error
Check item
Setting
[8112]
SNMP communication failure
Classification
Network error
Check item
Setting
[8121]
Domain authentication error: Domain authentication error
Classification
Network error
Check item
Setting
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Verify the access point name setting and mechanism used for association
same as Access Point setting.
Wireless Certificate verification failure
Verify the certificate settings used for association.
An error occurred during SNMP data writing.
Check if the parameter entered in the application is correct. Check if the
entered department code and box password are correct.
If the error still occurs after the correct parameter is entered, restart the
equipment and the application.
SNMP communication failed.
Check if there is any problem in the application.
An unidentified domain authentication error occurred during the connection
of domain controller.
Check the network configuration of this equipment and then reconnect to
the domain controller.