Download Print this page

Toshiba e-STUDIO556 Service Manual page 619

Hide thumbs Also See for e-STUDIO556:

Advertisement

05/08
Mode
Element
Sub
element
08
Setting
System
Fax
Mode
08
Setting
Printer
Laser
Mode
08
Setting
Printer
Paper
Mode
feeding
08
Setting
Printer
Paper
Automatic change of
Mode
feeding
paper source
08
Setting
Printer
Laser
Mode
08
Setting
Printer
Laser
Mode
08
Setting
Printer
Laser
Mode
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
3875
4004
4010
Auto
4011
4012
4013
4014
Details
Default
Acceptable
code
value
value
Address confirmation
Refer to
for multiple
contents
destinations
Polygonal motor
0
0~5
rotation speed at
ready status
Default setting of
0
0~6
paper source
PPC
1
1~2
Pre-running rotation
0
0~2
of polygonal motor
Polygonal motor
0
0~1
rotational status
switching at the Auto
Clear Mode
Rotational status of
0
0~1
polygonal motor on
standby
50
RAM
Contents
0-1
SYS Enable this setting to display the address confirmation
screen before sending fax to prevent wrong
transmission when multiple destination addresses are
specified.
0: Disabled 1: Enabled
<Default value>
JPC: 1
Others: 0
M
0: Rotation speed for printing
1: Rotation speed for copying
2: 10000 rpm
3: Not used
4: Not used
5: Not used
SYS 0: A4/LT 1: Tandem LCF 2: 1st drawer 3: 2nd drawer 4:
3rd drawer 5: 4th drawer 6: Option LCF
SYS Sets whether or not changing the drawer automatically
to the other drawer with the paper of the same size
when paper in the selected drawer has run out.
1: Only in the same paper direction
2: In both the same and different paper directions
SYS Sets whether or not switching the polygonal motor from
the standby rotation to the normal rotation when the
original is set on the RADF or the platen cover is
opened.
0: Valid (when using RADF and the original is set
manually)
1: Invalid
2: Valid (when using RADF only)
SYS Sets whether or not switching the polygonal motor from
the normal rotation to the standby rotation at the Auto
Clear Mode. 0: Valid 1: Invalid
SYS Sets the rotational status of polygonal motor on
standby.
0: Rotated (The rotation speed is set at 08-4004.)
1: Stopped
Proce
Servic
dure
e UI
1
1
1
1
Yes
1
1
1

Hide quick links:

Advertisement

loading