Download Print this page

Toshiba e-STUDIO556 Service Manual page 350

Hide thumbs Also See for e-STUDIO556:

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
08
Setting
Process
Image quality
Mode
control
e-STUDIO556/656/756/856
Item
Subitem
Drum surface
potential sensor
Drum surface
potential sensor
Sub-
Default
Code
Details
code
value
2844
1
Image quality closed-
0
loop control(Laser
power)
2845
Image quality open-
0
loop control
2846
Transfer output
0
correction control
switching against
surface potential
2850
Counter for number of
0
control abnormality
2851
Control setting
0
2873
Number of times of
0
sensor abnormality
2876
Image quality control/
20
Auto-start print
volume setting 1
2877
Image quality control/
50
Auto-start print
volume setting 2
2878
Condition setting of
4
image quality control
auto-start
2891
0
Maximum number of
5
times of image quality
closed-loop control
correction (Contrast
voltage)
7
Acceptable
RAM
Contents
value
0~1
M
0: Enabled 1: Disabled
0~1
M
0: Enabled 1: Disabled
0~2
M
0: Control OFF 1: Table 1 applied 2: Table 2 applied
0~16
M
0~1
M
0: Enabled 1: Disabled
0~16
M
The number of times the image quality closed-loop
control error has occurred is displayed. When the
equipment has been repaired and the cause of the error
has been evaluated after the appearance of a warning
message (IQC), reset the counter to switch off.
0~30
M
The printing interval to perform the image quality
closed-loop control is set. Default: 2000 sheets (Setting
value x 100 sheets)
1~99
M
The image quality closed-loop control is performed in a
shorter printing interval than the one set in 08-2876 only
when the equipment has been left inactive for a long
time (including power-OFF).Default: 500 sheets (Setting
value x 10 sheets)
0~24
M
When the equipment has been left in warming-up for
more than the specified period of time, the image
quality closed-loop control is performed. This period is
set in this code.Default: 4 (Unit: hours)
0~10
M
The maximum number of correction which the image
quality closed-loop control (contrast voltage) can be
performed is set.
Proce
Servic
dure
e UI
4
1
1
1
Yes
1
Yes
1
Yes
1
1
1
4

Hide quick links:

Advertisement

loading