Download Print this page

Toshiba e-STUDIO556 Service Manual page 575

Hide thumbs Also See for e-STUDIO556:

Advertisement

05/08
Mode
Element
Sub
element
08
Setting
Process
Fuser
Mode
Setting
Process
Fuser
Low temperature
08
Mode
waiting
Setting
Process
Fuser
Low temperature
08
Mode
waiting
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
2060
Temperature setting
2079
Temperature setting
2079
Details
Default
Acceptable
code
value
value
Threshold of low
7
0~11
temperature
environment control
0
Thick paper 1
Refer to
0~12
(Normal temperature
contents
environment)
1
Thick paper 1
Refer to
0~12
(Normal temperature
contents
environment)
6
RAM
Contents
M
The boundary temperature of the low and normal
temperature control can be set.
0: 0°C 1: 5°C 2: 9°C 3: 10°C 4: 12°C 5: 14°C 6: 15°
C 7: 16°C 8: 17°C 9: 18°C 10: 19°C 11: 20°C
M
Sets the temperature at which low-temperature
warming-up control starts.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657:
JPC: 4
TWD: 5
Others: 6
e-STUDIO757/857:
JPC: 6
Others: 8
* The setting value of this code is applied when "0"
(disable) is set to the code 08-2226-2
M
Sets the temperature at which low-temperature
warming-up control starts.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657: 9
e-STUDIO757/857: 10
* The setting value of this code is applied when "1"
(enable) is set to the code 08-2226-2
Proce
Servic
dure
e UI
1
4
4

Hide quick links: