8.4.5
Blurred image
Defective area
Paper
Bedewed scanner
Drum
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Fig. 8-5
Step
Check items
1
Is the paper in the drawer or LCF
damp?
2
Is the scanner bedewed?
3
Is the drum surface wet or dirty?
8 - 243
Prescription
Change paper. Avoid storing paper in
damp place.
Clean the scanner.
Wipe the drum with a piece of dry
cloth.
*
Do not use alcohol or other
organic solvents.
e-STUDIO556/656/756/856/557/657/757/857