Jumpers And User Adjustments; Selecting Whether Local Faults Will Be Monitored By The Global Frame Status; Figure 5-1: Jumper Locations - evertz MultiFrame 7700 Manual

Optical to electrical converter for ds3/e3 signals
Hide thumbs Also See for MultiFrame 7700:
Table of Contents

Advertisement

7700 MultiFrame Manual
7707OE-DS3/E3 Optical to Electrical Converter for DS3/E3 Signals
5.

JUMPERS AND USER ADJUSTMENTS

5.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
The FRAME STATUS jumper J7, located at the top front of the module determines whether local faults (as
shown by the Local Fault indicator) will be connected to the 7700FR frame's global status bus.
FRAME STATUS:
To monitor faults on this module with the frame status indicators (on the Power
Supply FRAME STATUS LED's and on the Frame's Fault Tally output) install this
jumper in the On position (default).
When this jumper is installed in the Off position local faults on this module will not
be monitored.
7707OE-DS3/E3-8
LOCAL FAULT
/ MODULE OK
SIGNAL VALID
OUTPUT FAULT
CARRIER FAULT
OUTPUT
RCLK/BYP/PATTERN
CONTROL
LOCAL/REMOTE
UPGRADE
UPGRADE/RUN

Figure 5-1: Jumper Locations

LEVEL 2
HI/LOW
LEVEL 3
HI/LOW
LEVEL4
HI/LOW
Revision 1.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

7707oe-ds37707oe-e3

Table of Contents