Chapter 9 List Commands; List:step:count <Nr1; List:step:voltage <Nr1>,<Nrf - ITech IT-M3100D Programming Manual

Programmable dc power supply
Hide thumbs Also See for IT-M3100D:
Table of Contents

Advertisement

LIST:STEP:COUNt <NR1>
This command sets the total steps of the list program.
Syntax
LIST:STEP:COUNt <NR1>
Arguments
<1-100>
Default value
Not applicable
Example
LIST:STEP:COUNt 1
Query command
LIST:STEP:COUNt?
Returns
NR1
LIST:STEP:VOLTage <NR1>,<NRf+>
This command sets the voltage value of the nth step in the list program.
Syntax
LIST:STEP:VOLTage <NR1>,<NRf+>
Arguments
<1-100>,<MINimum-MAXimum|MINimum|MAXimum>
Default value
Not applicable
Example
LIST:STEP:VOLT 1,100.00
Query command
LIST:STEP:VOLTage? <NR1>

Chapter 9 List Commands

Copyright © Itech Electronic Co., Ltd.