Programmable dc power supply
Hide thumbs Also See for IT-M3100D:
Table of Contents

Advertisement

DDE
3
EXE
4
CME
5
NU
6
PON
7
Status Byte Register
NU
0
NU
1
EAV
2
QUES
3
MAV
4
ESB
5
RQS/MSS
6
OPER
7
Copyright © Itech Electronic Co., Ltd.
A device-specific error, including a
8
self-test error, calibration error or other
device-specific error occurred.
16
An execution error occurred.
32
A command syntax error occurred.
not used
0 is returned.
Power has been cycled since the last
128
time the event register was read or
cleared.
not used
0 is returned.
not used
0 is returned.
4
Error buffer available.
This bit is set to 1 when any one status
8
of enabled query status register
changes.
16
Output buffer available.
Bit ESB is set to 1 when the status of
32
an enabled standard event status.
64
Register changes.
If the status of enabled operation
128
register changes, then this bit is set to
1.