Query command
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent[:OVER]:PROTection[:LEVel]
<NRf+>
This command sets the over-current limit of the power supply.
Syntax
[SOURce:]CURRent[:OVER]:PROTection[:LEVel] <NRf+>
Parameters
<NRf+> MIN TO MAX
Default value
MAX
Example
CURR:PROT 3.500
Query command
[SOURce:]CURRent[:OVER]:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent[:OVER]:PROTection:DELay
<NRf+>
This command sets the over-current delay time of the power supply.
Syntax
[SOURce:]CURRent[:OVER]:PROTection:DELay <NRf+>
Parameters
<NRf+> 0.00-10.00
Default value
10.00S