Storage module LEDs

Storage module LEDs
The front panel and LED layout shown in the following illustration is an example. Depending on your specific model, the LEDs might be
different.
Item LED
Item
LED
1
1
Drawer status
2
UID
3
Health status
4
Drive status (in priority order) Solid amber
5
Drawer power
1
The drive drawer must be closed within five minutes after it is opened.
Status
Status
Definition
Definition
Solid green
Drive drawer is closed
Flashing green Drive drawer is open
Flashing amber Thermal warning, close the drive drawer
Solid blue
One or more drives are being located
Flashing blue
Firmware flash in progress
Off
No drives are being located
Green
Normal operation
Flashing amber Degraded condition
Flashing red
Critical condition
One or more drives failed
Flashing amber One or more drives are predicted to fail
Flashing green One or more drives are rebuilding or transforming
Solid green
One or more drives are members of a logical drive
Off
No drives are configured by a RAID controller
Green
Storage module is in use, do not remove
Off
Storage module is not in use, safe to remove