with either a component or a blank.
4. Place the –48V DC power supply on a flat, level work surface.
5. Open the input connector on the power supply.
6. Using a T25 Torx screwdriver, disconnect and remove the power cables.
Retain the cables and T25 screws for to install on the replacement –48V DC power supply.
Removing and replacing a –48V DC power supply